Skip to main content

Table 2 Median irradiance loss (lowest value; maximum value) of indirect restorative materials at varying thicknesses (mm)

From: Effect of thickness on irradiance loss and temperature rise in indirect restorative materials: an in vitro study

Irradiance loss

0.5 mm

1 mm

1.5 mm

2 mm

p

GRA

52.1 (51.3;55.3) a B

71.2 (70.1;73.9) ab AB

79 (69.7;79.5) ab AB

79.9 (79.1;80.6) b AB

0.001

VSC

69.2 (69;70.3) a A

75.4 (74.7;76.4) ab A

83.8 (83.1;84.3) bc A

89.4 (89.3;90.1) c A

< 0.001

VBM

57.8 (57;60.4) a AB

63.3 (62.8;65.2) ab B

68.4 (67.7;69.2) bc B

71.8 (69.4;72.8) c B

< 0.001

p

0.002

0.002

< 0.002

< 0.002

 
  1. *Lowercase letters denote varying thicknesses of the material within the same row, while uppercase letters signify statistical differences (Kruskal-Wallis) among different materials in the same column