- Research
- Open access
- Published:
Influence of the print orientation and cast thickness on the accuracy of DLP master casts for fixed dental prostheses
BMC Oral Health volume 25, Article number: 532 (2025)
Abstract
Background
This study aimed to evaluate the influence of different print orientations and external shell thickness on the accuracy of master casts printed with direct light processing (DLP) technology for fixed dental prostheses.
Methods
Seventy-two maxillary hollow master casts were printed with a DLP printer from a standard tessellation language (STL) reference file with dental preparations for a single crown and a 3-unit fixed partial denture. Study groups consisted of six groups (n = 12) according to the print orientation (0, 10, and 20 degrees) and the external shell thickness of the cast (2 mm and 4 mm). Each specimen was digitized with a laboratory scanner. Discrepancies between the reference STL and the experimental STL of the printed cast were measured by using the root mean square (RMS) error. Data were statistically analyzed using one-way ANOVA and Tukey’s HDS test to evaluate the trueness, and precision was assessed using the Levene test (α = 0.05).
Results
No significant differences were found in the overall trueness and precision between the groups analyzed for the print orientation and the shell thickness. The 2-mm external shell thickness demonstrated the best trueness on selected points.
Conclusions
The print orientation in the range of 0 to 20 degrees and the cast thickness did not influence the overall accuracy of DLP-printed master casts for fixed prostheses with clinically acceptable range values. Trueness was affected by the external shell thickness on selected points.
Introduction
In recent years, dentistry, especially prosthodontics, has evolved significantly with the development of digital technologies such as subtractive manufacturing and additive manufacturing (AM) techniques [1,2,3,4,5]. One of the most important applications of AM in dentistry is printing dental casts [6, 7]. Accurate dental arch replicas are essential for fabricating prostheses with proper internal and marginal fit, proximal contacts and contours, and occlusion [8]. Physical casts are particularly necessary when ceramic layering is applied and when details about adjacent and occluding teeth are crucial [9]. Poor cast accuracy can lead to misfit and extra adjustments, potentially compromising the prosthesis structure and reducing longevity, sometimes requiring work repetition [8]. Therefore, studying master casts fabricated by AM methods is crucial to ensure their reproduction accuracy and reliability in clinical applications.
To fabricate dental casts, only three of the seven categories described by the American Society for Testing and Materials (ASTM) are the most commonly used AM technologies, which are material jetting (Multijet), material extrusion or fused deposition modeling (FDM), and vat-polymerization, including stereolithography (SLA) and digital light processing (DLP) [10]. Studies have shown that SLA, DLP, and PolyJet technologies are particularly accurate in fabricating full-arch dental models [10]. Recently, vat-polymerization has emerged as the predominant AM technology for producing dental casts [11]. Differences in the vat-polymerization technology are based on the light source used for the polymerization [12, 13]; SLA uses ultraviolet (UV) laser light to polymerize the object point by point, offering greater precision in a longer time, while DLP uses a digital light projection screen to polymerize a cross-sectional layer of resin completely at once, offering high precision in a shorter time [5, 10, 12, 13].
Accuracy is defined by trueness and precision [14]. According to the International Organization for Standardization (ISO) [15], the trueness of a printed cast is defined as the deviation from the original STL file, while precision refers to repeatability, measured as the deviation of the casts from each other. Previous studies have evaluated the accuracy of diagnostic models by establishing a clinically acceptable manufacturing range (100 mm to 300 mm) [16,17,18,19,20,21,22,23,24,25,26,27]. This accuracy is determined by a multitude of variables, such as the type of resin [28,29,30], intraoral scanning [31], the 3D printer technology used [32,33,34], the geometry of the design [35, 36], slicing procedures [29], the support structures [33,34,35, 37,38,39], post-processing methods [40, 41], printing orientation [42, 43], and base type [44, 45]. For this reason, controlling these factors is crucial for obtaining highly accurate dental models. However, the scientific literature on the impact of these variables on the accuracy of printed master casts is scarce and often contradictory [46, 47]. Furthermore, there is a lack of established guidelines for optimal print settings.
Among all factors, printing orientation can significantly influence the mechanical properties of printed materials, thereby affecting printing accuracy [48, 49]. Another factor is the shell thickness. Shell thickness in 3D printing refers to the thickness of the outer walls of a printed object and plays a critical role in determining the final print’s accuracy, strength, and surface finish [50]. Therefore, it is crucial to validate the clinical effectiveness of various 3D printer settings through comparative evaluations of volumetric discrepancies and quantitative deviations among AM-fabricated complete-arch casts produced [51]. Understanding and improving the accuracy of 3D-printed prosthetic models is crucial for achieving optimized outcomes in prosthesis fit, functionality, treatment success, durability, and longevity facilitated by minimizing replacements, streamlined fabrication processes, and enabling customization tailored to individual patient needs [52]. Therefore, the aim of this in vitro study was to evaluate the effect of the external shell thickness and the print orientation on the accuracy (trueness and precision) of master casts for fixed prosthodontics printed with an industrial DLP 3D printer. The null hypothesis was that no differences would be found in the accuracy (trueness and precision) of the DLP master casts manufactured with different print orientations and external shell thickness.
Methods
Master cast design
A maxillary master cast was scanned using a dental lab scanner (T710; Medit, Seoul, South Korea) with an accuracy of 4 μm to obtain an STL reference file named STL0. The master cast was a 3D-printed reference model designed to replicate a clinical scenario with dental preparations for cut-back zirconia restorations. The preparations included a single crown on the right first molar and a 3-unit fixed partial denture (FPD) extending from the left central incisor to the left canine (Fig. 1A). The abutment teeth were designed with a chamfer finish line, rounded preparation angles, an axial reduction of 1 mm, and a 6-degree convergence angle to optimize prosthetic adaptation (Fig. 1B and C).
(A) An overview of a printed master cast with two frequent dental preparation designs for fixed cut-back zirconia restorations. (B) The abutment teeth for a three-unit fixed partial denture (FPD) from the left maxillary central incisor to the left maxillary canine. (C) The abutment tooth for a single crown on the right first maxillary molar
Printer settings and study groups
The reference STL0 file was used to fabricate the experimental hollow casts using a DLP printer (Microlay Versus 385, Microlay 3D Printers, Madrid, Spain) with a 50 μm layer thickness, a horizontal resolution of 65 μm, and a vertical resolution (Z-axis) ranging from 100 to 200 μm. The prints were produced using a methacrylate-based resin (FotoDent model2 385 nm beige, Dreve, Unna, Germany) with a viscosity of 0.8–1.2 Pa·s, a flexural strength of ≥ 85 MPa, an elongation at break of ≥ 8%, an elastic modulus of ≥ 1,900 MPa, and a final hardness of 80–86 Shore D. Prior to the study, an expert operator (I.G.G.) calibrated the 3D printer to ensure accuracy.
Six groups were created based on the external shell thickness of each printed cast: 2 mm and 4 mm, and the print orientation used to fabricate the casts: 0-, 10-, and 20-degree (Table 1). The sample size calculation was conducted using a software program (G*Program 3.1.9.4). The calculation revealed a minimum of 12 casts per group, with an effect size of 1.2 at 0.8 power and a significance level of 0.05. A total of 72 master casts were included in the study.
Post-processing procedure for casts and superimposition
After printing, all specimens underwent a similar post-processing procedure following the manufacturer’s instructions. Rinsing was carried out by washing with 96% isopropyl alcohol at 20 °C and 50% humidity for 10 min, and then the casts were dried and polymerized using a curing unit (Otoflash G171, NK-Optik) for 6 min. All specimens were stored at room temperature (23ºC) in a dark container. Each printed cast was digitized using the same dental lab scanner (T710), which was calibrated before data acquisition and after the 12 scans of each group, following the manufacturer’s recommendations, and no later than 48 h after printing. To avoid errors in the superimposition of the STL generated, irregular areas were eliminated. The STL files were imported into a reverse engineering software program (Geomagic Control X; 3D Systems, Rock Hill, SC) for further analysis.
The casts were aligned and superimposed by using the best-fit technique [43, 53]. The measurements obtained in the STL0 file were used to measure the discrepancy with the experimental STL files. The root mean square (RMS) and average maximum and minimum values were displayed in the software. Furthermore, 36 points were marked in critical areas of each experimental cast—including the cusps of all teeth, the finish line, and the middle of the pontic area—to evaluate deviations from the STL0 file based on point location (anterior or posterior) (Fig. 2; Table 2). Additionally, in the regions designated for fixed prostheses, reference points 5, 6, 7, 13, 16, 21, 22, 23, 24, 25, 26, 27, and 28 were analyzed along the X, Y, and Z axes. The buccolingual variation was assessed along the X axis, mesiodistal variation along the Y axis, and occlusogingival variation along the Z axis. By evaluating these deviations, it was possible to determine whether, despite the overall model showing no significant differences in accuracy based on RMS values, discrepancies might still occur in the critical areas essential for restoration fabrication. Specifically, deviations in the X axis could result in improper seating on the finish line or over-contouring, while discrepancies in the Y axis could cause the restoration to sit incorrectly on the finish line or lose contact with adjacent mesial and distal teeth. Similarly, variations in the Z axis could lead to an inadequate fit, either failing to sit on the finish line or leaving excessive occlusal space that would need to be compensated for with cement, ultimately compromising the restoration’s adaptation.
Comparisons between groups and statistical analysis
To evaluate the external shell thickness, the following comparisons were established between groups G1 and G4, G2 and G5, and G3 and G6. To assess the print orientation, differences were established between the groups G1 and G2, G2 and G3, G1 and G3, G4 and G5, G5 and G6, and G4 and G6. The overall cast accuracy (trueness and precision) and the accuracy at the selected 36 points were evaluated. Trueness was defined as the closeness of each of the experimental casts with the reference scan, and precision was defined as the RMS error variations or standard deviation (SD) per group [43, 53].
The Shapiro-Wilk test revealed that the RMS data presented normal distributions (p > 0.05). One-way ANOVA and the post hoc Tukey HDS multiple pairwise comparisons were employed to analyze the overall trueness. Precision was assessed by using the Levene test. For the accuracy analysis of the selected points, given the non-normality of data, the Kruskal Wallis test was applied. The statistical analysis was performed with statistical software (IBM SPSS Statistics, v.26; IBM Corp, Armonk, NY). (α = 0.05).
Results
The overall minimum, maximum, and mean ± SD RMS error discrepancies (trueness ± precision) are presented in Table 3. The overall trueness mean values obtained for all the casts of the different groups ranged between (0.103 mm and 0.194 mm). Group 1 showed the lowest trueness (0.145 mm), while Group 3 had the best trueness (0.131 mm). One-way ANOVA revealed no significant differences among the groups. No differences were found for the external shell thickness between G1with G4 (p = 0.429), G2 with G5 (p = 0.853), and G3 with G6 (p = 0.522). Likewise, no differences were observed for the print orientation: with G2 (p = 1), G1 with G3 (p = 1), G2 with G3 (p = 1), G4 with G5 (p = 1), G4 with G6 (p = 1), and G5 with G6 (p = 1). Regarding the overall precision, the Levene test showed no significant differences (p = 0.139) among the groups. Group 3 obtained the best precision value, and Group 2 the lowest (Fig. 3).
When the comparison between the reference points was made, the Kruskal-Wallis test revealed differences in trueness for the external shell thickness. The groups with 2 mm thickness showed better trueness compared to the groups with 4 mm thickness (Table 4). No differences (p > 0.05) were found for the print orientation. Furthermore, a relationship between the points marked in the anterior area and those marked in the posterior region of the cast could not be demonstrated. Finally, when the comparison was made in the X, Y, and Z axis at the selected points on the areas to receive the fixed prosthesis, no differences in trueness were found for the print orientation. However, differences were observed for the external shell depending on the point and axis (Table 5) (Fig. 4A, B, C). The groups with 2 mm thickness demonstrated better trueness for the incisal edge, canine cuspid, and first molar vestibular and palatine mesial cuspid in the X, Y, and Z axis. Regarding the finish line of the abutment teeth, only the canine points showed differences in the three axes. The groups with 4 mm thickness obtained the best trueness (Fig. 4D).
(A): Surface characteristic analysis of the printed casts based on print orientation (G1); (B): Surface characteristic analysis of the printed casts based on print orientation (G2); (C): Surface characteristic analysis of the printed casts based on print orientation (G3); (D): Surface characteristic analysis of the printed casts based on internal cast thickness (G1, G4)
Discussion
Based on the results of the present study, the print orientations and shell thickness of the casts evaluated showed no differences in the overall trueness and precision. However, differences were found in the accuracy of the shell thickness when compared to the reference points evaluated. Therefore, the null hypothesis was partially accepted, as no statistically significant differences were found at the overall model level, but significant differences did emerge upon evaluating specific selected points. The partial differences can be attributed to the fact that when evaluating the model globally, the discrepancies among millions of points tend to average out or cancel each other. However, when assessing discrepancies at a single point, this averaging effect does not occur. The printed master casts evaluated presented a discrepancy trueness value ranging from − 0.141 mm to 0.145 mm. The printed casts manufactured at 0-degree and 2 mm shell thickness had the highest mean value, while the lowest discrepancies were observed in the 10-degree and 2-mm thickness groups.
The trueness values observed in this study ranged from 103 μm to 194 μm. These deviations quantify the differences between the printed casts and the original STL reference file under the selected printing conditions. Although they fall within the range reported by previous studies [16,17,18,19,20,21,22,23,24,25,26,27] using similar additive manufacturing technologies—representing an expected level of accuracy for dental model fabrication—these values should not be interpreted as thresholds of clinical acceptability. This study focused solely on the accuracy of the 3D-printed casts themselves and did not evaluate the cumulative discrepancies that may arise throughout the complete workflow of prosthesis fabrication, including internal and marginal fit. Therefore, the results must be considered strictly within the scope of cast manufacturing accuracy.
Regarding the variable print orientation, in the study, the 10-degree casts obtained the best trueness, and the 20-degree cast had the best precision. However, no differences in trueness and precision between the different print angulations evaluated (0-, 10-, and 20-degree) were observed. The authors are unaware of previous studies evaluating this variable for full-arch master casts for fixed prostheses, and it was not possible to compare the results of the study. Prior studies evaluating the influence of the print orientation on the accuracy of casts are sparse, and they were made on diagnostic casts. In addition, there is no homogeneity among the studies, and it is thus difficult to draw accurate conclusions and compare the results, as they did not use the same AM technology and degree of orientation. The findings aligned with Short et al. [47], who found minimal discrepancies at 0° and 20° on diagnostic casts, and Revilla-Leon et al. [54], who demonstrated superior trueness at 0° on occlusal devices using an SLA printer. Maneiro Lojo et al. [43] achieved optimal trueness at 22.5° and precision at 67.5°. Ko et al. [46], utilizing a DLP printer, observed the greatest discrepancies at 0° on diagnostic casts. Most authors noted increased differences with greater build orientation yet consistently found best trueness results between 0° and 22° for diagnostic models. This in vitro study assesses the accuracy (trueness and precision) of treatment models crucial for ensuring fixed prosthesis fit. Consequently, the study focused exclusively on angles of 0°, 10°, and 20°. The hollow cast base design with an external shell thickness of 2 and 4 mm was the second variable evaluated in the study.
The results showed the best accuracy for the 2-mm thickness casts and the best precision for the 4-mm thickness casts, although no differences could be demonstrated between 2- and 4-mm thickness. The results are consistent with the only previous study, to the best knowledge of the authors, that evaluated the accuracy of full-arch hollow casts printed with a DLP printer and different shell thicknesses (1- and 2-mm) [45]. Limited studies assessed the influence of the base design on the accuracy of full-arch casts. The cast base can be created using different designs. The solid base is used by orthodontists, while in prosthodontics, there are no recommendations on the optimal base cast design [44, 45, 55]. Revilla-Leon et al. evaluated the accuracy of casts with three base designs: hollow, honeycomb, and solid, using a material jetting printer and a DLP printer. The results showed that the hollow base obtained the best accuracy (34.00 ± 45.00 μm) [44]. Park et al. [8] used a DLP printer to print U-shaped casts with two types of resin. The mean trueness values did not differ between both groups, but there was a distribution of the values in the lower 50% in relation to the median value, which could be explained by the two types of resin used, which is reflected in a contraction of the posterior teeth and a need for a stabilization structure of the transverse arch [8]. Shin et al. [56] developed a study with two types of U-shaped arches, without a palate or with a transverse arch plate attached to the palate area. Each group was subdivided into five groups: 1.5-mm and 4-mm thick shell cast, hexagon-filled cast, roughly-filled cast, and fully-filled cast. The results exhibited the best accuracy (trueness and precision) for the transverse arch plate regardless of the intaglio structure [56]. Camardella et al. [24] carried out a study with three different types of bases: regular base, horseshoe-shaped base, and horseshoe-shaped base with a bar, as well as two types of printers (DLP and Polyjet). The results showed that the regular and horseshoe-shaped base with a bar were accurate, regardless of the 3D printer used [24]. However, Park et al. [8] evaluated the dimensional accuracy of 3D complete-arch printed casts with four different printer technologies, showing the results of dimensional variations for the assessed groups. Likewise, Rungrojwittayakul et al. reported that the accuracy of 3D-printed casts was affected by the printer technology regardless of the base design [55]. The hollow base design is commonly used in dental laboratories for economic reasons, as it minimizes material usage and reduces manufacturing time [44, 55, 56]. This rationale was one of the factors in selecting internal shell thicknesses of 2 mm and 4 mm, as optimizing material consumption is essential for efficiency. However, further studies are necessary to evaluate the influence of the base cast design and the shell thickness with different printers on the accuracy of the printed casts.
In the study, differences in the print orientation trueness could not be demonstrated between the anterior or posterior zone of the casts. However, when the selected points were analyzed, most areas showed better results in casts with 2 mm thickness than with 4 mm thickness, regardless of the angulation degree. Likewise, a cast with 2 mm thickness demonstrated better trueness for the abutment tooth (cuspid and incisal edge) in the three axes. No differences were found for the reference points at the finish line except for the canine. This aspect is significant because the selected points are located in areas of maximum height on the cast, which are essential for ensuring precise adjustments in the final restoration. Achieving greater trueness with a 2 mm shell thickness at these critical points enhances the passive fit of the restoration and improves occlusal accuracy, ultimately contributing to better prosthetic adaptation and clinical outcomes. The evaluation of deviations in the X, Y, and Z directions is a widely accepted approach to assessing the accuracy of printed dental casts. Previous studies have used point-based measurements to analyze discrepancies between experimental and reference models. For instance, Rungrojwittayakul et al. [55] established 48 measurement points on diagnostic casts produced with different 3D printers to evaluate overall discrepancies. However, their study did not specifically assess deviations along the X, Y, and Z axes, nor did it distinguish between the anterior and posterior sectors of the cast, limiting its applicability to understanding spatial variations in accuracy [55]. Similarly, Yoo et al. investigated the accuracy of treatment models for posterior fixed prostheses by measuring deviations at selected points on a prepared molar and a contact point. However, their methodology did not account for axis-specific deviations, and their study utilized different printers and printing parameters, making direct comparisons with our findings difficult [57].
The accuracy of DLP-printed dental models can be influenced by multiple factors related to the printer’s optical and mechanical components. In the X and Y directions, potential inaccuracies stem primarily from the resolution of the DLP engine and the projection system. The DLP technology relies on a digital micromirror device (DMD) to project light patterns onto the resin vat, where the polymerization of each layer occurs. However, the precision of this projection is affected by the pixel size and uniformity of the light intensity across the build platform. Minor distortions in light distribution or pixel placement can lead to small deviations in trueness, particularly in areas with fine details such as margins and occlusal surfaces. In the Z direction, inaccuracies may arise due to the printer’s mechanical configuration, rigidity, and the control of the Z-axis elevation. The layer-by-layer curing process depends on precise vertical movement, which is controlled by a stepper motor and guide rails. Mechanical instability, slight misalignments, or variations in resin shrinkage during curing can introduce discrepancies along this axis. The resolution of the Z-axis (100–200 μm) is typically coarser than the horizontal resolution (65 μm), potentially contributing to greater variations in vertical accuracy compared to lateral dimensions. Furthermore, variations in resin properties, such as viscosity, polymerization kinetics, and post-curing shrinkage, may differentially affect accuracy in different spatial directions. To ensure the highest possible accuracy, the printer was calibrated by an expert operator before the study. However, despite these efforts, inherent limitations in DLP printing technology and resin behavior may still contribute to small deviations, particularly in complex anatomical structures.
Additionally, the alignment technique plays a fundamental role in determining the accuracy of 3D-printed dental models [58]. In this study, a global best-fit alignment method was used, ensuring a robust comparison of the printed casts by superimposing STL files based on millions of verification points. This process was performed only when the discrepancy was less than 1 μm, guaranteeing an optimal alignment. While a local best-fit alignment focused on the abutment teeth could have provided additional insights, it might not accurately reflect deviations along the X, Y, and Z axes. These axes are critical in evaluating the settlement and adaptation of the final prosthetic restoration. Additionally, distributing reference points across the entire model permitted the analysis of differences between anterior and posterior regions, further strengthening the validity of the findings.
The comparison of this study’s results with previous research is challenging due to variations in AM technologies, printer types, print orientations, resin compositions, cast base designs, and measurement methodologies. Multiple parameters influence the accuracy of AM-fabricated casts (trueness and precision), yet previous studies have not comprehensively analyzed all these factors together. By specifically analyzing discrepancies in the X, Y, and Z directions, this study provides a more detailed understanding of how dimensional accuracy varies in different spatial planes. This approach allows for determining whether deviations in trueness are uniform across the cast or if certain regions are more prone to inaccuracies. This level of detail is particularly relevant for fixed prosthodontics, where precise adaptation in all three spatial axes is critical for optimal fit and function. Consequently, the absence of standardized protocols integrating all these variables makes it difficult to establish definitive guidelines for manufacturing each type of dental product using AM technologies.
Limitations of the current study included the utilization of a singular AM technology, a specific type of resin, uniform printing layer thickness, consistent post-processing procedures, and a standardized base cast design. Another limitation was the use of a global best-fit alignment method, which, while ensuring a standardized assessment, may reduce localized discrepancies by averaging deviations across the entire model. This could potentially obscure minor variations in critical areas such as the abutment teeth, where precise adaptation is essential for prosthetic fit. Future investigations should comprehensively analyze all factors influencing the precision of printed master casts, including varying layer thicknesses, diverse configurations and placements of support structures, and different post-processing protocols. Additionally, research should assess these variables across various types of 3D printers and base cast designs to enhance the robustness of findings. Clear and standardized protocols tailored to each clinical indication and specific 3D dental printer type are essential. Moreover, future studies should incorporate both global and local alignment techniques to provide a detailed evaluation of regional accuracy variations, particularly in areas critical for prosthetic adaptation and clinical outcomes.
The practical implications of this study are significant for both dentists and dental technicians. By adhering to the conditions outlined—specifically using the same additive manufacturing technology, 3D printer, resin material, and post-processing protocols—highly accurate dental models can be achieved for fixed prosthesis treatments. For dental laboratories, these findings define the optimal printing parameters, including print orientation and external shell thickness, for producing treatment models with this specific type of printer. The standardized approach recommends a 2 mm shell thickness and a 20-degree orientation angle, which has been shown to enhance efficiency and accuracy in model fabrication. Similarly, in clinical settings equipped with this particular 3D printer, these findings provide essential guidelines for achieving precise treatment models. This ensures that both dental professionals and patients benefit from consistent and reliable printing parameters, ultimately streamlining workflow and improving clinical outcomes.
Conclusions
Within the limitations of this study, the following conclusions were drawn:
-
1.
The print orientation tested did not influence the accuracy (trueness and precision) of master casts printed with the DLP printer tested.
-
2.
The shell thickness of the master casts printed with the DLP printer tested did not influence the overall accuracy (trueness and precision). However, when analyzing the selected points, the master casts with 2 mm thickness had better trueness than the 4 mm thickness.
-
3.
All printed master casts achieved a clinically acceptable trueness.
Data availability
The data presented in this study are available upon request from the corresponding author.
References
Revilla-León M, Gómez-Polo M, Vyas S, Barmak AB, Gallucci GO, Att W, et al. Artificial intelligence models for tooth-supported fixed and removable prosthodontics: A systematic review. J Prosthet Dent. 2023;129(2):276–92.
Rexhepi I, Santilli M, D’Addazio G, Tafuri G, Manciocchi E, Caputi S, Sinjari B. Clinical applications and mechanical properties of CAD-CAM materials in restorative and prosthetic dentistry: A systematic review. J Funct Biomater. 2023;14(8).
Young JM, Altschuler BR. Laser holography in dentistry. J Prosthet Dent. 1977;38(2):216–25.
van Noort R. The future of dental devices is digital. Dent Mater. 2012;28(1):3–12.
Horn TJ, Harrysson OL. Overview of current additive manufacturing technologies and selected applications. Sci Prog. 2012;95(Pt 3):255–82.
Atria PJ, Bordin D, Marti F, Nayak VV, Conejo J, Benalcázar Jalkh E, et al. 3D-printed resins for provisional dental restorations: comparison of mechanical and biological properties. J Esthet Restor Dent. 2022;34(5):804–15.
Joda T, Ferrari M, Gallucci GO, Wittneben JG, Brägger U. Digital technology in fixed implant prosthodontics. Periodontol 2000. 2017;73(1):178–92.
Park JM, Jeon J, Koak JY, Kim SK, Heo SJ. Dimensional accuracy and surface characteristics of 3D-printed dental casts. J Prosthet Dent. 2021;126(3):427–37.
Alzahrani SJ. Fabrication of definitive cast for complete mouth rehabilitation by using Resin-Transfer coping. Cureus. 2022;14(8):e27831.
Németh A, Vitai V, Czumbel ML, Szabó B, Varga G, Kerémi B, et al. Clear guidance to select the most accurate technologies for 3D printing dental models– A network meta-analysis. J Dent. 2023;134:104532.
Wang G, Wang S, Dong X, Zhang Y, Shen W. Recent progress in additive manufacturing of ceramic dental restorations. J Mater Res Technol. 2023;26:1028–49.
Al Rashid A, Ahmed W, Khalid MY, Koç M. Vat photopolymerization of polymers and polymer composites: processes and applications. Additive Manuf. 2021;47:102279.
Pagac M, Hajnys J, Ma Q-P, Jancar L, Jansa J, Stefek P, Mesicek J. A review of vat photopolymerization technology: materials, applications, challenges, and future trends of 3D printing. Polymers. 2021;13(4):598.
Sim J-Y, Jang Y, Kim W-C, Kim H-Y, Lee D-H, Kim J-H. Comparing the accuracy (trueness and precision) of models of fixed dental prostheses fabricated by digital and conventional workflows. J Prosthodontic Res. 2019;63(1):25–30.
ISO/TC 261, ASTM Committee F42. Additive manufacturing — General principles — Fundamentals and vocabulary: ISO/ASTM 52900:2021; 2021 [2:[Available from: https://www.iso.org/standard/74514.html
Favero CS, English JD, Cozad BE, Wirthlin JO, Short MM, Kasper FK. Effect of print layer height and printer type on the accuracy of 3-dimensional printed orthodontic models. Am J Orthod Dentofac Orthop. 2017;152(4):557–65.
Etemad-Shahidi Y, Qallandar OB, Evenden J, Alifui-Segbaya F, Ahmed KE. Accuracy of 3-Dimensionally printed Full-Arch dental models: A systematic review. J Clin Med. 2020;9(10).
Park ME, Shin SY. Three-dimensional comparative study on the accuracy and reproducibility of dental casts fabricated by 3D printers. J Prosthet Dent. 2018;119(5):861.e1-.e7.
Kim SY, Shin YS, Jung HD, Hwang CJ, Baik HS, Cha JY. Precision and trueness of dental models manufactured with different 3-dimensional printing techniques. Am J Orthod Dentofac Orthop. 2018;153(1):144–53.
Brown GB, Currier GF, Kadioglu O, Kierl JP. Accuracy of 3-dimensional printed dental models reconstructed from digital intraoral impressions. Am J Orthod Dentofac Orthop. 2018;154(5):733–9.
Jin SJ, Jeong ID, Kim JH, Kim WC. Accuracy (trueness and precision) of dental models fabricated using additive manufacturing methods. Int J Comput Dent. 2018;21(2):107–13.
Rebong RE, Stewart KT, Utreja A, Ghoneima AA. Accuracy of three-dimensional dental resin models created by fused deposition modeling, stereolithography, and polyjet prototype technologies: A comparative study. Angle Orthod. 2018;88(3):363–9.
Dietrich CA, Ender A, Baumgartner S, Mehl A. A validation study of reconstructed rapid prototyping models produced by two technologies. Angle Orthod. 2017;87(5):782–7.
Camardella LT, de Vasconcellos Vilella O, Breuning H. Accuracy of printed dental models made with 2 prototype technologies and different designs of model bases. Am J Orthod Dentofac Orthop. 2017;151(6):1178–87.
Rossini G, Parrini S, Castroflorio T, Deregibus A, Debernardi CL. Diagnostic accuracy and measurement sensitivity of digital models for orthodontic purposes: A systematic review. Am J Orthod Dentofac Orthop. 2016;149(2):161–70.
De Luca Canto G, Pachêco-Pereira C, Lagravere MO, Flores-Mir C, Major PW. Intra-arch dimensional measurement validity of laser-scanned digital dental models compared with the original plaster models: a systematic review. Orthod Craniofac Res. 2015;18(2):65–76.
Hazeveld A, Huddleston Slater JJ, Ren Y. Accuracy and reproducibility of dental replica models reconstructed by different rapid prototyping techniques. Am J Orthod Dentofac Orthop. 2014;145(1):108–15.
Alharbi N, Osman R, Wismeijer D. Effects of build direction on the mechanical properties of 3D-printed complete coverage interim dental restorations. J Prosthet Dent. 2016;115(6):760–7.
Reymus M, Fabritius R, Keßler A, Hickel R, Edelhoff D, Stawarczyk B. Fracture load of 3D-printed fixed dental prostheses compared with milled and conventionally fabricated ones: the impact of resin material, build direction, post-curing, and artificial aging-an in vitro study. Clin Oral Investig. 2020;24(2):701–10.
Revilla-León M, Umorin M, Özcan M, Piedra-Cascón W. Color dimensions of additive manufactured interim restorative dental material. J Prosthet Dent. 2020;123(5):754–60.
Piedra-Cascón W, Adhikari RR, Özcan M, Krishnamurthy VR, Revilla-León M, Gallas-Torreira M. Accuracy assessment (trueness and precision) of a confocal based intraoral scanner under twelve different ambient lighting conditions. J Dent. 2023;134:104530.
Mosaddad SA, Peláez J, Panadero RA, Ghodsi S, Akhlaghian M, Suárez MJ. Do 3D-printed and milled tooth-supported complete monolithic zirconia crowns differ in accuracy and fit? A systematic review and meta-analysis of in vitro studies. J Prosthet Dent. 2024.
Puebla K, Arcaute K, Quintana R, Wicker RB. Effects of environmental conditions, aging, and build orientations on the mechanical properties of ASTM type I specimens manufactured via stereolithography. Rapid Prototyp J. 2012;18(5):374–88.
Braian M, Jimbo R, Wennerberg A. Production tolerance of additive manufactured polymeric objects for clinical applications. Dent Mater. 2016;32(7):853–61.
Ide Y, Nayar S, Logan H, Gallagher B, Wolfaardt J. The effect of the angle of acuteness of additive manufactured models and the direction of printing on the dimensional fidelity: clinical implications. Odontology. 2017;105(1):108–15.
Wu D, Zhao Z, Zhang Q, Qi HJ, Fang D. Mechanics of shape distortion of DLP 3D printed structures during UV post-curing. Soft Matter. 2019;15(30):6151–9.
Cho HS, Park WS, Choi BW, Leu MC. Determining optimal parameters for stereolithography processes via genetic algorithm. J Manuf Syst. 2000;19(1):18–27.
Alharbi N, Osman RB, Wismeijer D. Factors influencing the dimensional accuracy of 3D-Printed Full-Coverage dental restorations using stereolithography technology. Int J Prosthodont. 2016;29(5):503–10.
Unkovskiy A, Bui PH, Schille C, Geis-Gerstorfer J, Huettig F, Spintzyk S. Objects build orientation, positioning, and curing influence dimensional accuracy and flexural properties of stereolithographically printed resin. Dent Mater. 2018;34(12):e324–33.
Mostafavi D, Methani MM, Piedra-Cascón W, Zandinejad A, Revilla-León M. Influence of the rinsing postprocessing procedures on the manufacturing accuracy of Vat-Polymerized dental model material. J Prosthodont. 2021;30(7):610–6.
Mostafavi D, Methani MM, Piedra-Cascón W, Zandinejad A, Att W, Revilla-León M. Influence of polymerization postprocessing procedures on the accuracy of additively manufactured dental model material. Int J Prosthodont. 2023;36(4):479–85.
Revilla-León M, Jordan D, Methani MM, Piedra-Cascón W, Özcan M, Zandinejad A. Influence of printing angulation on the surface roughness of additive manufactured clear silicone indices: an in vitro study. J Prosthet Dent. 2021;125(3):462–8.
Maneiro Lojo J, Alonso Pérez-Barquero J, García-Sala Bonmatí F, Agustín-Panadero R, Yilmaz B, Revilla-León M. Influence of print orientation on the accuracy (trueness and precision) of diagnostic casts manufactured with a daylight polymer printer. J Prosthet Dent. 2023.
Revilla-León M, Piedra-Cascón W, Methani MM, Barmak BA, Att W. Influence of the base design on the accuracy of additive manufactured casts measured using a coordinate measuring machine. J Prosthodont Res. 2022;66(1):68–74.
Revilla-León M, Piedra-Cascón W, Aragoneses R, Sadeghpour M, Barmak BA, Zandinejad A, Raigrodski AJ. Influence of base design on the manufacturing accuracy of vat-polymerized diagnostic casts: an in vitro study. J Prosthet Dent. 2023;129(1):166–73.
Ko J, Bloomstein RD, Briss D, Holland JN, Morsy HM, Kasper FK, Huang W. Effect of build angle and layer height on the accuracy of 3-dimensional printed dental models. Am J Orthod Dentofac Orthop. 2021;160(3):451–e82.
Short MM, Favero CS, English JD, Kasper FK. Impact of orientation on dimensional accuracy of 3D-printed orthodontic models. J Clin Orthod. 2018;52(1):13–20.
Tahayeri A, Morgan M, Fugolin AP, Bompolaki D, Athirasala A, Pfeifer CS, et al. 3D printed versus conventionally cured provisional crown and Bridge dental materials. Dent Mater. 2018;34(2):192–200.
Shim JS, Kim JE, Jeong SH, Choi YJ, Ryu JJ. Printing accuracy, mechanical properties, surface characteristics, and microbial adhesion of 3D-printed resins with various printing orientations. J Prosthet Dent. 2020;124(4):468–75.
Shin S-H, Kwon J-S, Shim J-S, Kim J-E. Evaluating the Three-Dimensional printing accuracy of Partial-Arch models according to outer wall thickness: an in vitro study. Materials. 2021;14(22):6734.
Piedra-Cascón W, Krishnamurthy VR, Att W, Revilla-León M. 3D printing parameters, supporting structures, slicing, and post-processing procedures of vat-polymerization additive manufacturing technologies: A narrative review. J Dent. 2021;109:103630.
Brenes C, Bencharit S, Fox T. Evaluation of prosthetic outcomes and patient satisfaction with 3D-Printed Implant-Supported fixed prosthesis. Cureus. 2023;15(7):e42537.
Revilla-León M, Supaphakorn A, Barmak AB, Rutkunas V, Kois JC. Influence of print orientation on the intaglio surface accuracy (trueness and precision) of tilting stereolithography definitive resin-ceramic crowns. J Prosthet Dent. 2023.
Revilla-León M, Cascos-Sánchez R, Zeitler JM, Barmak AB, Kois JC, Gómez-Polo M. Influence of print orientation and wet-dry storage time on the intaglio accuracy of additively manufactured occlusal devices. J Prosthet Dent. 2024;131(6):1226–34.
Rungrojwittayakul O, Kan JY, Shiozaki K, Swamidass RS, Goodacre BJ, Goodacre CJ, Lozada JL. Accuracy of 3D printed models created by two technologies of printers with different designs of model base. J Prosthodont. 2020;29(2):124–8.
Shin SH, Lim JH, Kang YJ, Kim JH, Shim JS, Kim JE. Evaluation of the 3D printing accuracy of a dental model according to its internal structure and Cross-Arch plate design: an in vitro study. Mater (Basel). 2020;13(23).
Yoo SY, Kim SK, Heo SJ, Koak JY, Kim JG. Dimensional accuracy of dental models for Three-Unit prostheses fabricated by various 3D printing technologies. Mater (Basel). 2021;14(6).
Vincze ZÉ, Kovács ZI, Vass AF, Borbély J, Márton K. Evaluation of the dimensional stability of 3D-printed dental casts. J Dent. 2024;151:105431.
Acknowledgements
The authors thank Dr. Carmen Bravo, Centre of Data Processing, Computing Service for Research Support, Complutense University of Madrid, for assistance with the statistical analysis and the Prótesis S.A. dental laboratory for fabricating the printed casts.
Funding
None.
Author information
Authors and Affiliations
Contributions
Conceptualization: I.G.G. and M.J.S.; Methodology: I.G.G. and J.P.; Software: I.G.G. and V.R.A.; Validation: M.J.S. and J.P.; Formal analysis: I.G.G. and V.R.A.; Investigation: I.G.G. and C.L.S.; Resources: M.J.S. and C.L.S.; Data curation: I.G.G. and J.P.; Writing—original draft preparation: I.G.G., V.R.A., and C.L.S.; Writing— review and editing: M.J.S., J.P., and S.A.M.; Visualization: I.G.G.; Supervision: M.J.S. and J.P.; Project administration: M.J.S. and J.P. All authors have read and approved the published version of the manuscript.
Corresponding authors
Ethics declarations
Ethics approval and consent to participate
Not applicable.
Consent for publication
Not applicable.
Competing interests
The authors declare no competing interests.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Electronic supplementary material
Below is the link to the electronic supplementary material.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc-nd/4.0/.
About this article
Cite this article
García-Gil, I., Rodríguez Alonso, V., López Suárez, C. et al. Influence of the print orientation and cast thickness on the accuracy of DLP master casts for fixed dental prostheses. BMC Oral Health 25, 532 (2025). https://doiorg.publicaciones.saludcastillayleon.es/10.1186/s12903-025-05944-0
Received:
Accepted:
Published:
DOI: https://doiorg.publicaciones.saludcastillayleon.es/10.1186/s12903-025-05944-0